| Revex W570  
| Type: | SWR/Power meter |  
| Frequency range: | 1.6-1300 MHz in four ranges with two sensors 
 1.6-160 MHz (sensor 1)
 400-525 MHz (sensor 2)
 700-1100 MHz (sensor 2)
 1240-1300 MHz (sensor 2)
 |  
| Power measure ranges: | 5 W 20 W
 200 W
 |  
| Insertion loss: | 1.6-160 MHz: <0.2 dB 400-525 MHz: <0.1 dB
 700-1100 MHz: <0.15 dB
 1240-1300 MHz: <0.2 dB
 |  
| Dimensions (W*H*D): | 120*72*85 mm (excluding sensor 2) |  
| Weight: | 830 gr |  
| Manufactured: | Japan, 198x-20xx |  
| Other: | Accuracy: ±10% of full scale (15% on 5 W range) Minimum power for accurate SWR measurement is 3 W
 2*SO-239 (sensor 1), 2*N-jack (sensor 2)
 
 New price 1987 in the US: $129.00
 |  